Cussons's Official Blog. Updates of our activity for Educational Engineering Range and Marine Hydrodynamics Division.// Español: Actualizaciones para equipos didácticos para Universidades, Ingeniería, Naval, Marina, Mecatrónica, Civil, Renovables y muchos más.// Français: Nouveautés sur les équipements didactiques d’ingénierie destinés aux Universités, Grandes Écoles d’Ingénieurs, Ingénierie Navale,Maritime, Mécatronique, Génie Civil, Énergies Renouvelables et bien d’autres
Search This Blog
Monday, 17 August 2015
Monday, 3 August 2015
P6100 Hydraulics Bench and Accessories
Hydraulics Bench - Series and parallel pump |
The Cussons Hydraulic Bench provides the basic services for pumping and volumetric measurement of water supply. Various optional modules are available to form a comprehensive laboratory facility which enables a detailed Mechanics of Fluids Experimental Course to be followed. The equipment is designed to provide a clear visual appreciation of hydraulic principles and has been featured by +BBC News on the Open University Mechanics of Fluids course.
- Centrifugal pump characteristics
- Flow in pipes and pipe fittings
- Flow through orifices and over weirs
- Flow in channels
- Bernoulli's experiment
- Water flow measurement
- Hydrostatics
- Free and forced vortices
- Hydraulic machines
- Pipe networks
- Reynolds number
For more information:http://www.cussons.co.uk/
Monday, 22 June 2015
P3210 Heat Transfer Bench with cross Flow Heat Exchanger
A range of experiments in the field of Heat Transfer has been developed for the basic Air Flow Bench to meet the needs of this growing area of study.
FEATURES
- Large range of add-on experiments in heat transfer, air flow and aerodynamics.
- Well instrumented including dual sloping manometer, barometer and pitot static tube.
- Additional equipment easily and quickly fitted.
- Enables a series of forced convection heat transfer coefficients to be derived.
- Data logging outputs of heater current and voltage, surface temperature and air temperature available as an option.
PRINCIPLE EXPERIMENTS
- To determine the relationship between Nusselts and Reynolds numbers applied to a single heated tube positioned transversely to a stream of air.
- To determine the effect of change of diameter on the heat transfer coefficient to a single tube in cross flow.
- To determine the effect of change of position of the heated tube within a cross flow tube bundle.
Tuesday, 26 May 2015
P6510 NETWORK OF PIPES APPARATUS
The Cussons P6510 Network of Pipes Apparatus allows students to conduct a range of experiments on a system of interconnecting series and parallel pipe networks as well as fluid distribution systems.
EXPERIMENTAL NETWORKS
- Single pipe
- Two pipes in series
- Four pipes in series
- Two pipes in parallel
- Four pipes in parallel
- Series parallel network with 3 or 4 elements
- A 3 pipe series network with a parallel bypass
- A distribution system with 2, 3, or 4 branches from a common manifold
- A long distribution system with 1, 2, 3 or 4 discharge points
- A ring main distribution system with 1, 2, 3 or 4 discharge points
For more information:http://www.cussons.co.uk/
Thursday, 12 March 2015
P7674 Ejector Bench
The principle of operation of an ejector is simple: a high velocity steam jet blows into the ejector throat and thereby produces a suction which draws a fluid into the throat at high velocity.
- Compact modular design
- Easy installation
- Comprehensive instrumentation
- Pressure test certificates supplied for major components
- Low capital cost
Steam Head Assembly
Mild steel steam header welded in accordance with BS2633 (1973) with a branch providing a steam supply to the ejector. The steam header is enclosed within a header box and fully insulated with mineral wool.
Certification
Inter-Connection of Steam Benches
To enable steam benches to be linked to form a system utilising a common steam supply and service system, the steam bench is supplied complete with:
- An interconnecting back panel and student work surface.
- A set of 4 stainless steel flexible hoses for the steam and service connections.
- A section of aluminium clad lagging for the flexible steam hose.
#ejector #BS2633 #steam #ejectorbench #steamjet #lagging #ejectorthroat
For more information:http://www.cussons.co.uk/
Wednesday, 25 February 2015
P9010e Turbojet Engine Test Stand
Cussons Turbojet Engine Test Stand provides a fully functioning, aero derivative small jet turbine.
Turbojets are used as high performance jet engines in aircraft and to provide the core of the very successful turbofan engines used on the great majority of airliners.
Cussons Turbojet Engine Test Stand provides a fully functioning, aero derivative small jet turbine. The jet turbine thrust can be measured and outputs from up to 230N can be achieved. The unit is provided with a mimic diagram displaying the temperatures of the gas flow and engine pressure ratio. Air flow, fuel flow and rotational speed measurement mean that an energy balance for the engine can be undertaken.
EXPERIMENTS / LEARNING CAPABILITIES
- Demonstration of the Turbo jet principle
- Performance analysis of a Turbojet at varying power
- Temperatures air inlet
- Fuel inlet compressor outlet
- Combustion chamber outlet
- Tail pipe stream
- Ambient air pressure
- Air inlet differential pressure
- Compressor outlet pressure
Wednesday, 4 February 2015
P9235 SPECTROANALYSER
The Cussons Spectroanalyser 3 has been developed to measure low concentrations of nitrogen as an impurity in certain rare gases, and has found particular applications with high purity argon.
- Measurement of trace amounts of nitrogen in high purity argon production and user systems
- Quality control of high purity/ultra-high purity argon cylinders
FEATURES
- 0-100 mV and 4-20 mA recorder outputs
- High and low level alarm contacts
- Analyser electronic self-check facility
- Design eliminates background interference
TECHNICAL SPECIFICATION
- Ranges: 0-10 vpm and 0-100 vpm Nitrogen in Argon
- Display: Analogue meter
- Limit of detection: Less than 1 vpm
- Sensitivity: Less than 1 vpm
- Zero drift: Less than 0.1 vpm per ºC
- Cycle/response time: Continuous/90% within 60 secs
- Accuracy: Depending on calibration gas available as it is a comparative method that is employed
- Sample flow rate: 2 litres per minute
- Sample inlet temperature: 10ºC minimum, 30ºC max.
- Sample inlet pressure: Optimum 0.35 to 1.05 bar g; maximum 3.5 bar g
- Sample outlet pressure: Maximum 0.15 bar g
- Sample pipework: 6mm or 1/4 OD stainless steel and PTFE
- Analogue output: 4-20 mA and 0-100 mV
- Alarm contacts: Adjustable high and low alarms with both normally open and closed voltage free contacts rated at 250V, 5A, AC non inductive
- Electrical supply: 110/220V, 60 Hz or 220/240V, 50 Hz single phase
#Spectroanalyser #argon #calibrationgas #purityargon #nitrogen #Analyserelectronic
For more information:http://www.cussons.co.uk/
Monday, 19 January 2015
P1906 Linear Vibration Apparatus
The P1906 Linear Vibration Apparatus provides the student with an introductory course of instruction and experiments on the subject of linear vibration.
FEATURES
- Vibration of a Spring Mass System
- Vibration of a Double Cantilever Beam
- Demonstration of Simple Harmonic Motion of a free body
- Demonstration of Hookes Law applied to a spring
1. BaIl Chatter Test
A vibration test illustrating simple harmonic motion theory.
2. Spring Rate Test
A demonstration of Hooke's Law.
3. Spring-Mm System Test
A test to verify the mass/frequency relationship of a vibrating spring-mass system.
4. Double Cantilever Beam
a) A determination of the cantilevers natural frequency.
b) A determination of the natural frequency of a loaded cantilever.
These are the main experiments which may be performed.
#Cantilever #Chatter #Spring-Mm #SpringMass #LinearVibration #Hooke's Law #Vibration
For more information:http://www.cussons.co.uk/
Monday, 12 January 2015
P5160 Friction Loss in Pipes and Fittings
Cussons P5160 Friction Loss in Pipes apparatus allows the student to study flow through pipes and fittings, investigate the relationship between flow and pressure drop and plot values of friction factor against Reynolds number.
EXPERIMENTAL CAPABILITIES
P5160 Friction Loss in Pipes |
- Flow through smooth pipes of differing diameters under laminar and turbulent flow conditions with logarithmic plot of friction factor f against Reynolds number (Stanton diagram).
- Flow through roughened pipes of different diameters under laminar and turbulent flow conditions with logarithmic plot of friction factor f against Reynolds number (Nikuradse diagram).
- Investigations of the flow/pressure drop relationship for an annular pipe, using the concept of equivalent hydraulic diameter.
- Investigation of pressure drops across various fittings enabling the results to be used to predict resistance coefficients or equivalent lengths.
Venturi meter |
- Investigation of various methods of flow measurement including variable area meter (Rotameter), Transparent Venturi Meter, Orifice Plate Meter and Pitot Static Tube
- Comparison of pressure drops across three different types of valve (i.e. ball valve, gate valve and seat valve) under different conditions of valve opening.
For more information:http://www.cussons.co.uk/
Subscribe to:
Posts (Atom)